At Feather River Aire Heating & Cooling, our priority is you, the customer. We are a family-owned, and locally operated full-service heating and air conditioning company located in Oroville, CA. We focus on bringing comfort to your home every season of the year. We help you create and maintain a healthy indoor climate in your home or commercial building.
Check out what some of our customers are saying about Feather River Aire Heating & Cooling – Heating and Air Conditioning services.
Recent Jobs and Reviews in Palermo, CA
Rated 5.0 out of 5 stars based on 3 customer reviews
Job Locations and Reviews
Brenden W.
Checked in
Ducting repair. Added sheetmetal repair 30" long. Put sealant between repair and ducting, screwed repair to ducting, taped the seams, and then coated tape and seams w duct sealant.
Palermo, CA 95968
Brenden W.
Checked in
Ducting repair. Added sheetmetal repair 30" long. Put sealant between repair and ducting, screwed repair to ducting, taped the seams, and then coated tape and seams w duct sealant.
Palermo, CA 95968
Brenden W.
Checked in
Ducting repair. Added sheetmetal repair 30" long. Put sealant between repair and ducting, screwed repair to ducting, taped the seams, and then coated tape and seams w duct sealant.
Palermo, CA 95968
Brenden W.
Checked in
Ducting repair. Added sheetmetal repair 30" long. Put sealant between repair and ducting, screwed repair to ducting, taped the seams, and then coated tape and seams w duct sealant.
Palermo, CA 95968
Brenden W.
Checked in
Ducting repair. Added sheetmetal repair 30" long. Put sealant between repair and ducting, screwed repair to ducting, taped the seams, and then coated tape and seams w duct sealant.
Palermo, CA 95968
Brenden W.
Checked in
Wallheater and HVAC assessment.
Palermo, CA 95968
Jacob S.
Checked in
Assessed york gas package unit for replacement. System has fire damage, the gas valve is not operating and the blower does not turn. System needs to be replaced.
Palermo, CA 95968
Jacob S.
Checked in
Performed heating maintenance and filter change on a trane gas package unit. Readings: Blower capacitor 14.25/15mfd, Blower amp draw 1.72/2.1A, Draft motor capacitor 1.89/2mfd, Draft motor amp draw .12/.22A, Carbon monoxide 0ppm, Temp rise 80-115. Heating at this time
Palermo, CA
Andrew R.
Checked in
Replaced two malfunctioning programmable thermostats. System is now heating well this time and set to a schedule.
Palermo, CA 95968
Jacob S.
Checked in
Performed heating maintenance and filter change on a lennox gas furnace. Readings: Blower capacitor 7.6/7.5mfd, Blower Amp draw 4.5A, Draft motor amp draw 1.8/1.9A, Carbon monoxide 0ppm, Temp rise 70-120F. Heating at this time.
Palermo, CA 95968
Review
Andrew R.
Checked in
Wire running from furnace to thermostat appears to be intermittently short. Recommendation is to replace wire to thermostat.
Palermo, CA 95968
Review
Brenden W.
Checked in
No heat. Unit is natural gas, lights and then shuts down. Blower is not coming on and limits out and shuts down. Also not getting a strong signal from flame sensor. Cleaned flame sensor and replaced 7.5?f blower capacitor (reading 1.85). Unit is running well.
Palermo, CA 95968
Review
Jacob S.
Checked in
Performed cooling maintenance on day & night split system. Replaced filter (1@14x24x1) and checked that thermostat is functioning. Checked disconnect and checked capacitor was within range. Verified that contactor is getting 240V and functioning. Checked compressor Amp draw and out door fan motor Amp draw. Visually inspected for leaks and exposed wires. Checked that condensate was draining. Washed condenser coil. Checked temperature split. System is operational and cooling at this time.
Palermo, CA 95968
Andrew R.
Checked in
Ductless system with three heads was using only one to manage the whole house. I recommended setting the other two a couple of degrees higher than the main head (instead of off) so that way the heat is better managed during the hot parts of the day. System cooling well at this time with temp splits between 22-25°.
Palermo, CA 95968